Curasynth

Curasynth / Models

What the platform computes, and how it says so.

Retrieval finds what has been measured. A decision usually needs more. These models run beside the data — some over the whole catalog on every release, some on demand — and all obey one rule.

On demand

Boltz-2: co-fold a drug with a target, and read the pose back.

An open, MIT-licensed model that folds a protein and a ligand together and predicts their affinity, run as a service beside the data.

  1. 01 · nameFrom a monograph, Predict binding names the partner.
  2. 02 · estimateA cost estimate comes back first.
  3. 03 · confirmIt runs under a dollar ceiling you set.
  4. 04 · landThe result is a new row against the pair, labeled predicted.
Buprenorphine at the mu, kappa and delta opioid receptors: predicted pIC50 beside measured Ki, with pose checks.
Buprenorphine at the μ, κ and δ opioid receptors: predicted potency beside the measured Ki, the pose checked for pocket and clashes.

More than a number

The pose is read for the model's own doubt — interface aligned error, per-residue confidence — and for what a chemist would check: contacts, buried area, clashes, and whether the ligand sits in the known pocket. The same service screens a drug's structural neighbors at its primary target.

The receptor-occupancy profile across an exposure ladder, predicted values marked.
The occupancy profile below it, with predicted values marked as such.

Over the whole catalog

Models that run on every release.

Precomputed for every entity with the inputs, landed as bridge tables, and rebuilt as a new vintage when the method or the data changes — never in place.

Ranking

A composite that asks about this disease

Several parts under your own weights, across the evidence a target decision actually turns on — human genetics, tractability and chemical matter, dependency and expression in the disease's own lines, and clinical precedent. Parts that mean nothing outside oncology weigh zero there and show as a dash rather than a number.

Type 2 diabetes returns PPARG, GLP1R, ACE, DPP4, SLC5A2 — how it is actually treated.

Pharmacology

Receptor occupancy and target engagement

Every drug's targets solved together for occupancy across a 1 nM–1 µM exposure ladder, the measured range becoming the interval, scored for liability burden with the primary target excluded.

261,772 occupancy rows · 30,835 liability screens

Safety

Pharmacovigilance with shrinkage

4.2 million deduplicated cases into one 2×2 table per drug and term, scored by PRR, ROR and EBGM with intervals plus a sex-by-age adjusted ratio. A signal is a hypothesis for review, never an incidence.

864,709 scored signals · 2023 Q3 – 2026 Q2

Clinical

Arm-level and pooled trial effects

Where a study has posted results, its arms are compared from reported counts; trials of the same comparison in the same disease are pooled, so absence reads as absence.

230,987 arm effects · 19,236 pooled comparisons

Genetics

Dependency, copy number, collateral lethality

Dependency rolled up per target, in organoids as well as on plastic; co-deletion from TCGA copy number; together, a passenger deleted beside a tumor suppressor whose paralog the tumor now depends on.

39,275 collateral-lethality candidates

Binding

Consensus potency over censored measurements

Duplicates across sources removed first, then one median in p-affinity space per pair, with the count, the sources, whether any value was censored, and which source won precedence.

461,919 measurements → 145,727 pairs

Chemistry

Standardization, similarity, properties

Every ingredient standardized before it gets an identity. Morgan fingerprints give each drug its twenty nearest neighbors; a CNS score and a blood–brain-barrier screen for every drug.

11,758 drugs · 71,610 neighbor rows

Structure

Served structures and their annotation

A render decision made once per target: the experimental co-crystal where one exists with a ligand of interest, otherwise the predicted structure — each solved one linked to its paper.

79,269 structures · 116,960 structure–paper links

Literature

Citation intent and stance

Each citing sentence classified for intent and stance, so a finding's lineage reads as confirmation, use or dispute rather than a count.

208,113,080 intent markers

Next, with technical partners

The methods we would rather call than build.

The registry that resolves a method to a backend was built so a partner's model is called from the same cited workflow, under the same provenance rules.

Open slot

Docking

Pocket-aware where a co-crystal exists, blind where it does not.

Open slot

ADMET

Endpoints fine-tuned on labeled data.

Open slot

Target validity

A calibrated model to replace hand-set constants.